OrcaSlicer use `M141/M191` command to control active chamber heater.
|
|
|
|
If `Activate temperature control` is checked, OrcaSlicer will insert `M191` command at the beginning of the gcode(before `Machine G-code`).
|
|

|
|
*Note: If the machine is equipped with an auxiliary fan, OrcaSlicer will automatically activate the fan during the heating period to help circulate air in the chamber.*
|
|
|
|
|
|
There are two chamber temperature variables available that we can use in `Machine G-code` to control the chamber temperature, if you prefer:
|
|
To access the chamber temperature set in the first filament, use:
|
|
`M191 S{chamber_temperature[0]}`
|
|
To use the overall chamber temperature, which is the highest chamber temperature set across all filaments, use:
|
|
`M191 S{overall_chamber_temperature}`
|
|
|
|
|
|
--------------------------Klipper--------------------------
|
|
If you are using Klipper, you can define these macros to control the active chamber heater.
|
|
Bellow is a reference configuration for Klipper.
|
|
*Note: Don't forget to change the pin name/values to the actual values you are using in the configuration*
|
|
|
|
```
|
|
[heater_generic chamber_heater]
|
|
heater_pin:PB10
|
|
max_power:1.0
|
|
# Orca note: here the temperature sensor should be the sensor you are using for chamber temperature, not the PTC sensor
|
|
sensor_type:NTC 100K MGB18-104F39050L32
|
|
sensor_pin:PA1
|
|
control = pid
|
|
pid_Kp = 63.418
|
|
pid_ki = 0.960
|
|
pid_kd = 1244.716
|
|
min_temp:0
|
|
max_temp:70
|
|
|
|
[gcode_macro M141]
|
|
gcode:
|
|
SET_HEATER_TEMPERATURE HEATER=chamber_heater TARGET={params.S|default(0)}
|
|
|
|
[gcode_macro M191]
|
|
gcode:
|
|
{% set s = params.S|float %}
|
|
{% if s == 0 %}
|
|
# If target temperature is 0, do nothing
|
|
M117 Chamber heating cancelled
|
|
{% else %}
|
|
SET_HEATER_TEMPERATURE HEATER=chamber_heater TARGET={s}
|
|
# Orca: uncomment the following line if you want to use heat bed to assist chamber heating
|
|
# M140 S100
|
|
TEMPERATURE_WAIT SENSOR="heater_generic chamber_heater" MINIMUM={s-1} MAXIMUM={s+1}
|
|
M117 Chamber at target temperature
|
|
{% endif %}
|
|
|
|
``` |