ENH: modify image and introduction text

Change-Id: Ib867b6bc7200405b470b6149213c46986abf4bcb
This commit is contained in:
liz.li 2023-07-07 10:10:57 +08:00 committed by Lane.Wei
parent d9b44245ad
commit cbaa6bf16c
6 changed files with 68 additions and 41 deletions

Binary file not shown.

Before

Width:  |  Height:  |  Size: 2.7 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 2.8 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 210 KiB

View file

@ -4,7 +4,7 @@
namespace Slic3r { namespace GUI {
#define CALIBRATION_START_PAGE_TEXT_MAX_LENGTH FromDIP(1000)
CalibrationStartPage::CalibrationStartPage(wxWindow* parent, wxWindowID id, const wxPoint& pos, const wxSize& size, long style)
:CalibrationWizardPage(parent, id, pos, size, style)
{
@ -15,11 +15,22 @@ void CalibrationStartPage::create_when(wxWindow* parent, wxString title, wxStrin
{
m_when_title = new wxStaticText(this, wxID_ANY, title);
m_when_title->SetFont(Label::Head_14);
m_when_title->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
m_when_title->Wrap(CALIBRATION_START_PAGE_TEXT_MAX_LENGTH);
m_when_content = new wxStaticText(this, wxID_ANY, content);
m_when_content->SetFont(Label::Body_14);
m_when_content->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
m_when_content->Wrap(CALIBRATION_START_PAGE_TEXT_MAX_LENGTH);
}
void CalibrationStartPage::create_about(wxWindow* parent, wxString title, wxString content)
{
m_about_title = new wxStaticText(this, wxID_ANY, title);
m_about_title->SetFont(Label::Head_14);
m_about_title->Wrap(CALIBRATION_START_PAGE_TEXT_MAX_LENGTH);
m_about_content = new wxStaticText(this, wxID_ANY, content);
m_about_content->SetFont(Label::Body_14);
m_about_content->Wrap(CALIBRATION_START_PAGE_TEXT_MAX_LENGTH);
}
void CalibrationStartPage::create_bitmap(wxWindow* parent, const wxBitmap& before_img, const wxBitmap& after_img)
@ -36,12 +47,20 @@ void CalibrationStartPage::create_bitmap(wxWindow* parent, const wxBitmap& befor
void CalibrationStartPage::create_bitmap(wxWindow* parent, std::string before_img, std::string after_img)
{
wxBitmap before_bmp = create_scaled_bitmap(before_img, nullptr, 400);
wxBitmap after_bmp = create_scaled_bitmap(after_img, nullptr, 400);
wxBitmap before_bmp = create_scaled_bitmap(before_img, nullptr, 350);
wxBitmap after_bmp = create_scaled_bitmap(after_img, nullptr, 350);
create_bitmap(parent, before_bmp, after_bmp);
}
void CalibrationStartPage::create_bitmap(wxWindow* parent, std::string img) {
wxBitmap before_bmp = create_scaled_bitmap(img, nullptr, 350);
m_images_sizer = new wxBoxSizer(wxHORIZONTAL);
m_bmp_intro = new wxStaticBitmap(parent, wxID_ANY, wxNullBitmap, wxDefaultPosition, wxDefaultSize, 0);
m_bmp_intro->SetBitmap(before_bmp);
m_images_sizer->Add(m_bmp_intro, 0, wxALL, 0);
}
CalibrationPAStartPage::CalibrationPAStartPage(wxWindow* parent, wxWindowID id, const wxPoint& pos, const wxSize& size, long style)
: CalibrationStartPage(parent, id, pos, size, style)
{
@ -60,8 +79,11 @@ void CalibrationPAStartPage::create_page(wxWindow* parent)
m_page_caption->show_prev_btn(false);
m_top_sizer->Add(m_page_caption, 0, wxEXPAND, 0);
create_when(parent,
_L("When you need Flow Dynamics Calibration"),
_L("uneven extrusion"));
_L("When you need Flow Dynamics Calibration"),
_L("We now have added the auto-calibration for different filaments, which is fully automated and the result will be saved into the printer for future use. You only need to do the calibration in the following limited cases:\
\n1. If you introduce a new filament of different brands / models or the filament is damp;\
\n2. if the nozzle is worn out or replaced with a new one;\
\n3. If the max volumetric speed or print temperature is changed in the filament setting."));
m_top_sizer->Add(m_when_title);
m_top_sizer->Add(m_when_content);
@ -69,18 +91,16 @@ void CalibrationPAStartPage::create_page(wxWindow* parent)
create_bitmap(parent, "cali_page_before_pa", "cali_page_after_pa");
m_top_sizer->Add(m_images_sizer, 0, wxALL, 0);
m_top_sizer->AddSpacer(PRESET_GAP);
auto about_title = new wxStaticText(parent, wxID_ANY, _L("About this calibration"));
about_title->SetFont(Label::Head_14);
about_title->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
m_top_sizer->Add(about_title);
auto about_text = new wxStaticText(parent, wxID_ANY, _L("After calibration, the linear compensation factor(K) will be recorded and applied to printing. This factor would be different if device, degree of usage, material, and material family type are different"));
about_text->SetFont(Label::Body_14);
about_text->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
m_top_sizer->Add(about_text);
create_about(parent,
_L("About this calibration"),
_L("Please find the details of Flow Dynamics Calibration from our wiki.\
\n\nUsually the calibration is unnecessary.When you start a single color / material print, with the \"flow dynamics calibration\" option checked in the print start menu, the printer will follow the old way, calibration the filament before the print; When you start a multi color / material print, the printer will use the default compensation parameter for the filament during every filament switch which will have a good result in most cases.\
\n\nPlease note there are a few cases that will make the calibration result not reliable: using a texture plate to do the calibration; the build plate is not sticky(please wash the build plate or apply gluestick!) ...You can find more from our wiki.\
\n\nThe calibration results have about 10 % jitter in our test, which may cause the result not exactly the same in each calibration.We are still investing the root cause."));
m_top_sizer->Add(m_about_title);
m_top_sizer->Add(m_about_content);
m_top_sizer->AddSpacer(PRESET_GAP);
m_action_panel = new CaliPageActionPanel(parent, CalibMode::Calib_PA_Line, CaliPageType::CALI_PAGE_START);
@ -156,31 +176,33 @@ void CalibrationFlowRateStartPage::create_page(wxWindow* parent)
m_top_sizer->Add(m_page_caption, 0, wxEXPAND, 0);
create_when(parent,
_L("When you need Flow Rate Calibration"),
_L("Over-extrusion or under extrusion"));
_L("After using Flow Dynamics Calibration, there are still some extrusion issues, such as:\
\n1. Over - Extrusion: If you see excess material on your printed object, forming blobs or zits, or the layers seem too thick, it could be a sign of over - extrusion.\
\n2. Under - Extrusion : Signs include missing layers, weak infill, or gaps in the print.This could mean that your printer isn't extruding enough filament.\
\n3. Poor Surface Quality : If the surface of your prints seems rough or uneven, this could be a result of an incorrect flow rate.\
\n4. Weak Structural Integrity : If your prints break easily or don't seem as sturdy as they should be, this might be due to under-extrusion or poor layer adhesion."));
m_top_sizer->Add(m_when_title);
m_top_sizer->Add(m_when_content);
m_top_sizer->AddSpacer(PRESET_GAP);
auto recommend_title = new wxStaticText(parent, wxID_ANY, _L("Flow Rate calibration is recommended when you print with:"));
recommend_title->SetFont(Label::Head_14);
recommend_title->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
m_top_sizer->Add(recommend_title);
auto recommend_text1 = new wxStaticText(parent, wxID_ANY, _L("material with significant thermal shrinkage/expansion, such as..."));
recommend_text1->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
recommend_text1->SetFont(Label::Body_14);
m_top_sizer->Add(recommend_text1);
auto recommend_text2 = new wxStaticText(parent, wxID_ANY, _L("materials with inaccurate filament diameter"));
recommend_text2->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
recommend_text2->SetFont(Label::Body_14);
m_top_sizer->Add(recommend_text2);
create_bitmap(parent, "cali_page_flow_introduction");
m_top_sizer->Add(m_images_sizer, 0, wxALL, 0);
m_top_sizer->AddSpacer(PRESET_GAP);
create_bitmap(parent, "cali_page_before_flow", "cali_page_after_flow");
m_top_sizer->Add(m_images_sizer, 0, wxALL, 0);
auto extra_text = new wxStaticText(parent, wxID_ANY, _L("Beyond fixing the noted printing defects, Flow Rate Calibration is crucial for foaming materials like LW-PLA used in RC planes. These materials expand greatly when heated, and calibration provides a useful reference flow rate to achieve good printing results with these special filaments."));
extra_text->SetFont(Label::Body_14);
extra_text->Wrap(CALIBRATION_START_PAGE_TEXT_MAX_LENGTH);
m_top_sizer->Add(extra_text);
m_top_sizer->AddSpacer(PRESET_GAP);
create_about(parent,
_L("About this calibration"),
_L("This flow rate calibration measures the ratio of expected to actual extrusion volumes. For Bambu Lab printer users using our official filaments, adjustments are seldom needed, as default settings ensure an optimal flow rate. Calibration is typically unnecessary with common filaments. Refer to our wiki article for more information.\
\n\nFlow Rate Calibration utilizes Bambu Lab's Micro-Lidar technology, directly measuring calibration the calibration patterns. However, please be advised that the efficacy and accuracy of this method may be compromised with specific types of materials. Particularly, filaments that are transparent or semi-transparent, sparkling-particled, or have a high-reflective finish may not be suitable for this calibration.\
\n\nThe calibration results may vary between each calibration or filament.We are still improving the accuracy and compatibility of this calibration."));
m_top_sizer->Add(m_about_title);
m_top_sizer->Add(m_about_content);
m_top_sizer->AddSpacer(PRESET_GAP);
m_action_panel = new CaliPageActionPanel(parent, CalibMode::Calib_Flow_Rate, CaliPageType::CALI_PAGE_START);
@ -254,20 +276,20 @@ void CalibrationMaxVolumetricSpeedStartPage::create_page(wxWindow* parent)
auto recommend_title = new wxStaticText(parent, wxID_ANY, _L("Max Volumetric Speed calibration is recommended when you print with:"));
recommend_title->SetFont(Label::Head_14);
recommend_title->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
recommend_title->Wrap(CALIBRATION_START_PAGE_TEXT_MAX_LENGTH);
m_top_sizer->Add(recommend_title);
auto recommend_text1 = new wxStaticText(parent, wxID_ANY, _L("material with significant thermal shrinkage/expansion, such as..."));
recommend_text1->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
recommend_text1->Wrap(CALIBRATION_START_PAGE_TEXT_MAX_LENGTH);
recommend_text1->SetFont(Label::Body_14);
m_top_sizer->Add(recommend_text1);
auto recommend_text2 = new wxStaticText(parent, wxID_ANY, _L("materials with inaccurate filament diameter"));
recommend_text2->Wrap(CALIBRATION_TEXT_MAX_LENGTH);
recommend_text2->Wrap(CALIBRATION_START_PAGE_TEXT_MAX_LENGTH);
recommend_text2->SetFont(Label::Body_14);
m_top_sizer->Add(recommend_text2);
m_top_sizer->AddSpacer(PRESET_GAP);
create_bitmap(parent, "cali_page_before_flow", "cali_page_after_flow");
create_bitmap(parent, "cali_page_before_pa", "cali_page_after_pa");
m_top_sizer->Add(m_images_sizer, 0, wxALL, 0);

View file

@ -23,12 +23,17 @@ protected:
wxBoxSizer* m_images_sizer;
wxStaticText* m_when_title;
wxStaticText* m_when_content;
wxStaticBitmap* m_before_bmp;
wxStaticBitmap* m_after_bmp;
wxStaticText* m_about_title;
wxStaticText* m_about_content;
wxStaticBitmap* m_before_bmp{ nullptr };
wxStaticBitmap* m_after_bmp{ nullptr };
wxStaticBitmap* m_bmp_intro{ nullptr };
void create_when(wxWindow* parent, wxString title, wxString content);
void create_about(wxWindow* parent, wxString title, wxString content);
void create_bitmap(wxWindow* parent, const wxBitmap& before_img, const wxBitmap& after_img);
void create_bitmap(wxWindow* parent, std::string before_img, std::string after_img);
void create_bitmap(wxWindow* parent, std::string img);
};
class CalibrationPAStartPage : public CalibrationStartPage

View file

@ -238,7 +238,7 @@ Temp_Calibration_Dlg::Temp_Calibration_Dlg(wxWindow* parent, wxWindowID id, Plat
// Settings
//
wxString start_temp_str = _L("Start temp: ");
wxString end_temp_str = _L("End end: ");
wxString end_temp_str = _L("End temp: ");
wxString temp_step_str = _L("Temp step: ");
auto text_size = wxWindow::GetTextExtent(start_temp_str);
text_size.IncTo(wxWindow::GetTextExtent(end_temp_str));