Updated chamber temperature control tooltips (#6517)
This commit is contained in:
parent
cd4de6be7e
commit
bcf45a332e
1 changed files with 10 additions and 4 deletions
|
@ -4755,15 +4755,21 @@ void PrintConfigDef::init_fff_params()
|
|||
|
||||
def = this->add("activate_chamber_temp_control",coBools);
|
||||
def->label = L("Activate temperature control");
|
||||
def->tooltip = L("Enable this option for chamber temperature control. An M191 command will be added before \"machine_start_gcode\"\nG-code commands: M141/M191 S(0-255)");
|
||||
def->tooltip = L("Enable this option for automated chamber temperature control. This option activates the emitting of an M191 command before the \"machine_start_gcode\"\n which sets the "
|
||||
"chamber temperature and waits until it is reached. In addition, it emits an M141 command at the end of the print to turn off the chamber heater, if present. \n\n"
|
||||
"This option relies on the firmware supporting the M191 and M141 commands either via macros or natively and is usually used when an active chamber heater is installed.");
|
||||
def->mode = comSimple;
|
||||
def->set_default_value(new ConfigOptionBools{false});
|
||||
|
||||
def = this->add("chamber_temperature", coInts);
|
||||
def->label = L("Chamber temperature");
|
||||
def->tooltip = L("Higher chamber temperature can help suppress or reduce warping and potentially lead to higher interlayer bonding strength for high temperature materials like ABS, ASA, PC, PA and so on."
|
||||
"At the same time, the air filtration of ABS and ASA will get worse.While for PLA, PETG, TPU, PVA and other low temperature materials,"
|
||||
"the actual chamber temperature should not be high to avoid cloggings, so 0 which stands for turning off is highly recommended"
|
||||
def->tooltip = L("For high-temperature materials like ABS, ASA, PC, and PA, a higher chamber temperature can help suppress or reduce warping and potentially lead to higher interlayer bonding strength. "
|
||||
"However, at the same time, a higher chamber temperature will reduce the efficiency of air filtration for ABS and ASA. \n\n"
|
||||
"For PLA, PETG, TPU, PVA, and other low-temperature materials, this option should be disabled (set to 0) as the chamber temperature should be low to avoid extruder clogging caused "
|
||||
"by material softening at the heat break.\n\n"
|
||||
"If enabled, this parameter also sets a gcode variable named chamber_temperature, which can be used to pass the desired chamber temperature to your print start macro, "
|
||||
"or a heat soak macro like this: PRINT_START (other variables) CHAMBER_TEMP=[chamber_temperature]. This may be useful if your printer does not support M141/M191 commands, or if you desire "
|
||||
"to handle heat soaking in the print start macro if no active chamber heater is installed."
|
||||
);
|
||||