@ -935,9 +935,13 @@ void CalibrationPresetPage::check_filament_compatible()
|
|||
wxString tips = wxString::Format(_L("%s is not compatible with %s"), m_comboBox_bed_type->GetValue(), incompatiable_filament_name);
|
||||
m_warning_panel->set_warning(tips);
|
||||
}
|
||||
m_has_filament_incompatible = true;
|
||||
update_show_status();
|
||||
} else {
|
||||
m_tips_panel->set_params(0, bed_temp, 0);
|
||||
m_warning_panel->set_warning("");
|
||||
m_has_filament_incompatible = false;
|
||||
update_show_status();
|
||||
}
|
||||
|
||||
Layout();
|
||||
|
@ -951,6 +955,46 @@ bool CalibrationPresetPage::is_filaments_compatiable(const std::vector<Preset*>&
|
|||
return is_filaments_compatiable(prests, bed_temp, incompatiable_filament_name, error_tips);
|
||||
}
|
||||
|
||||
bool CalibrationPresetPage::is_filament_in_blacklist(Preset* preset, std::string& error_tips)
|
||||
{
|
||||
if (m_ams_radiobox->GetValue() && wxGetApp().app_config->get("skip_ams_blacklist_check") != "true") {
|
||||
bool in_blacklist = false;
|
||||
std::string action;
|
||||
std::string info;
|
||||
std::string filamnt_type;
|
||||
preset->get_filament_type(filamnt_type);
|
||||
|
||||
if (preset->vendor) {
|
||||
DeviceManager::check_filaments_in_blacklist(preset->vendor->name, filamnt_type, in_blacklist, action, info);
|
||||
}
|
||||
|
||||
if (in_blacklist) {
|
||||
error_tips = info;
|
||||
if (action == "prohibition") {
|
||||
return false;
|
||||
}
|
||||
else if (action == "warning") {
|
||||
return true;
|
||||
}
|
||||
}
|
||||
else {
|
||||
error_tips = "";
|
||||
return true;
|
||||
}
|
||||
}
|
||||
if (m_ext_spool_radiobox->GetValue()) {
|
||||
if (m_cali_mode == CalibMode::Calib_PA_Line && m_cali_method == CalibrationMethod::CALI_METHOD_AUTO) {
|
||||
std::string filamnt_type;
|
||||
preset->get_filament_type(filamnt_type);
|
||||
if (filamnt_type == "TPU") {
|
||||
error_tips = _u8L("TPU is not supported for Flow Dynamics Auto-Calibration.");
|
||||
return false;
|
||||
}
|
||||
}
|
||||
}
|
||||
return true;
|
||||
}
|
||||
|
||||
bool CalibrationPresetPage::is_filaments_compatiable(const std::vector<Preset*> &prests,
|
||||
int& bed_temp,
|
||||
std::string& incompatiable_filament_name,
|
||||
|
@ -980,12 +1024,16 @@ bool CalibrationPresetPage::is_filaments_compatiable(const std::vector<Preset*>
|
|||
|
||||
return false;
|
||||
} else {
|
||||
// set for firset preset
|
||||
// set for first preset
|
||||
if (bed_temp == 0)
|
||||
bed_temp = bed_temp_int;
|
||||
}
|
||||
std::string display_filament_type;
|
||||
filament_types.push_back(item->config.get_filament_type(display_filament_type, 0));
|
||||
|
||||
// check is it in the filament blacklist
|
||||
if (!is_filament_in_blacklist(item, error_tips))
|
||||
return false;
|
||||
}
|
||||
|
||||
if (!Print::check_multi_filaments_compatibility(filament_types)) {
|
||||
|
@ -996,6 +1044,23 @@ bool CalibrationPresetPage::is_filaments_compatiable(const std::vector<Preset*>
|
|||
return true;
|
||||
}
|
||||
|
||||
void CalibrationPresetPage::update_plate_type_collection(CalibrationMethod method)
|
||||
{
|
||||
m_comboBox_bed_type->Clear();
|
||||
const ConfigOptionDef* bed_type_def = print_config_def.get("curr_bed_type");
|
||||
if (bed_type_def && bed_type_def->enum_keys_map) {
|
||||
for (int i = 0; i < bed_type_def->enum_labels.size(); i++) {
|
||||
if(btDefault + 1 + i == btPTE) {
|
||||
if (method == CalibrationMethod::CALI_METHOD_AUTO) {
|
||||
continue;
|
||||
}
|
||||
}
|
||||
m_comboBox_bed_type->AppendString(_L(bed_type_def->enum_labels[i]));
|
||||
}
|
||||
m_comboBox_bed_type->SetSelection(0);
|
||||
}
|
||||
}
|
||||
|
||||
void CalibrationPresetPage::update_combobox_filaments(MachineObject* obj)
|
||||
{
|
||||
if (!obj) return;
|
||||
|
@ -1119,6 +1184,11 @@ void CalibrationPresetPage::update_show_status()
|
|||
}
|
||||
}
|
||||
|
||||
if (m_has_filament_incompatible) {
|
||||
show_status(CaliPresetPageStatus::CaliPresetStatusFilamentIncompatible);
|
||||
return;
|
||||
}
|
||||
|
||||
show_status(CaliPresetPageStatus::CaliPresetStatusNormal);
|
||||
}
|
||||
|
||||
|
@ -1236,6 +1306,11 @@ void CalibrationPresetPage::show_status(CaliPresetPageStatus status)
|
|||
update_print_status_msg(msg_text, true);
|
||||
Enable_Send_Button(false);
|
||||
}
|
||||
else if (status == CaliPresetPageStatus::CaliPresetStatusFilamentIncompatible) {
|
||||
update_print_status_msg(wxEmptyString, false);
|
||||
Enable_Send_Button(false);
|
||||
}
|
||||
|
||||
Layout();
|
||||
}
|
||||
|
||||
|
@ -1342,6 +1417,7 @@ void CalibrationPresetPage::set_cali_filament_mode(CalibrationFilamentMode mode)
|
|||
|
||||
void CalibrationPresetPage::set_cali_method(CalibrationMethod method)
|
||||
{
|
||||
CalibrationWizardPage::set_cali_method(method);
|
||||
if (method == CalibrationMethod::CALI_METHOD_MANUAL && m_cali_mode == CalibMode::Calib_Flow_Rate) {
|
||||
wxArrayString steps;
|
||||
steps.Add(_L("Preset"));
|
||||
|
@ -1381,6 +1457,7 @@ void CalibrationPresetPage::init_with_machine(MachineObject* obj)
|
|||
{
|
||||
if (!obj) return;
|
||||
|
||||
// set nozzle value from machine
|
||||
bool nozzle_is_set = false;
|
||||
for (int i = 0; i < NOZZLE_LIST_COUNT; i++) {
|
||||
if (abs(obj->nozzle_diameter - nozzle_diameter_list[i]) < 1e-3) {
|
||||
|
@ -1403,22 +1480,29 @@ void CalibrationPresetPage::init_with_machine(MachineObject* obj)
|
|||
m_comboBox_nozzle_dia->SetSelection(NOZZLE_LIST_DEFAULT);
|
||||
}
|
||||
|
||||
// set bed type collection from machine
|
||||
if (m_cali_mode == CalibMode::Calib_PA_Line)
|
||||
update_plate_type_collection(m_cali_method);
|
||||
|
||||
// init default for filament source
|
||||
// TODO if user change ams/ext, need to update
|
||||
if ( !obj->has_ams() || (obj->m_tray_now == std::to_string(VIRTUAL_TRAY_ID)) )
|
||||
{
|
||||
m_ext_spool_radiobox->SetValue(true);
|
||||
m_ams_radiobox->SetValue(false);
|
||||
wxCommandEvent event(wxEVT_RADIOBUTTON);
|
||||
event.SetEventObject(this);
|
||||
wxPostEvent(this->m_ext_spool_radiobox, event);
|
||||
}
|
||||
else {
|
||||
m_ams_radiobox->SetValue(true);
|
||||
m_ext_spool_radiobox->SetValue(false);
|
||||
wxCommandEvent event(wxEVT_RADIOBUTTON);
|
||||
event.SetEventObject(this);
|
||||
wxPostEvent(this->m_ams_radiobox, event);
|
||||
}
|
||||
Layout();
|
||||
|
||||
// init filaments for calibration
|
||||
sync_ams_info(obj);
|
||||
}
|
||||
|
|
|
@ -118,6 +118,7 @@ enum CaliPresetPageStatus
|
|||
CaliPresetStatusNeedForceUpgrading,
|
||||
CaliPresetStatusNeedConsistencyUpgrading,
|
||||
CaliPresetStatusUnsupportedPrinter,
|
||||
CaliPresetStatusFilamentIncompatible,
|
||||
};
|
||||
|
||||
class CalibrationPresetPage : public CalibrationWizardPage
|
||||
|
@ -204,6 +205,7 @@ protected:
|
|||
|
||||
void check_filament_compatible();
|
||||
bool is_filaments_compatiable(const std::vector<Preset*>& prests);
|
||||
bool is_filament_in_blacklist(Preset* preset, std::string& error_tips);
|
||||
bool is_filaments_compatiable(const std::vector<Preset*>& prests,
|
||||
int& bed_temp,
|
||||
std::string& incompatiable_filament_name,
|
||||
|
@ -211,6 +213,7 @@ protected:
|
|||
|
||||
float get_nozzle_value();
|
||||
|
||||
void update_plate_type_collection(CalibrationMethod method);
|
||||
void update_combobox_filaments(MachineObject* obj);
|
||||
void update_show_status();
|
||||
void show_status(CaliPresetPageStatus status);
|
||||
|
@ -267,6 +270,7 @@ protected:
|
|||
CaliPresetPageStatus m_page_status { CaliPresetPageStatus::CaliPresetStatusInit };
|
||||
|
||||
bool m_show_custom_range { false };
|
||||
bool m_has_filament_incompatible { false };
|
||||
MachineObject* curr_obj { nullptr };
|
||||
};
|
||||
|
||||
|
|