NEW: add limitation of bed temperature
Change-Id: Ib25f28d8803a022678d67ee05cf1d0c48e8727c4 Signed-off-by: Stone Li <stone.li@bambulab.com>
This commit is contained in:
parent
1d827bd968
commit
3034ec7425
4 changed files with 49 additions and 0 deletions
|
@ -21,6 +21,7 @@
|
|||
"FUNC_ALTER_RESOLUTION": false
|
||||
},
|
||||
"camera_resolution":["720p"],
|
||||
"bed_temperature_limit": 100,
|
||||
"model_id": "C11",
|
||||
"printer_type": "C11"
|
||||
},
|
||||
|
|
|
@ -1138,6 +1138,7 @@ void MachineObject::parse_state_changed_event()
|
|||
|
||||
void MachineObject::parse_status(int flag)
|
||||
{
|
||||
is_220V_voltage = ((flag >> 3) & 0x1) != 0;
|
||||
if (xcam_auto_recovery_hold_count > 0)
|
||||
xcam_auto_recovery_hold_count--;
|
||||
else {
|
||||
|
@ -1164,6 +1165,22 @@ PrintingSpeedLevel MachineObject::_parse_printing_speed_lvl(int lvl)
|
|||
return PrintingSpeedLevel::SPEED_LEVEL_INVALID;
|
||||
}
|
||||
|
||||
int MachineObject::get_bed_temperature_limit()
|
||||
{
|
||||
if (printer_type == "BL-P001" || printer_type == "BL-P002") {
|
||||
if (is_220V_voltage)
|
||||
return 110;
|
||||
else {
|
||||
return 120;
|
||||
}
|
||||
} else {
|
||||
int limit = BED_TEMP_LIMIT;
|
||||
DeviceManager::get_bed_temperature_limit(printer_type, limit);
|
||||
return limit;
|
||||
}
|
||||
return BED_TEMP_LIMIT;
|
||||
}
|
||||
|
||||
bool MachineObject::is_sdcard_printing()
|
||||
{
|
||||
if (can_abort()
|
||||
|
@ -1772,6 +1789,7 @@ void MachineObject::reset()
|
|||
BOOST_LOG_TRIVIAL(trace) << "reset dev_id=" << dev_id;
|
||||
last_update_time = std::chrono::system_clock::now();
|
||||
m_push_count = 0;
|
||||
is_220V_voltage = false;
|
||||
camera_recording = false;
|
||||
camera_recording_when_printing = false;
|
||||
camera_timelapse = false;
|
||||
|
@ -3595,6 +3613,22 @@ std::vector<std::string> DeviceManager::get_resolution_supported(std::string typ
|
|||
return resolution_supported;
|
||||
}
|
||||
|
||||
bool DeviceManager::get_bed_temperature_limit(std::string type_str, int &limit)
|
||||
{
|
||||
bool result = false;
|
||||
if (DeviceManager::function_table.contains("printers")) {
|
||||
for (auto printer : DeviceManager::function_table["printers"]) {
|
||||
if (printer.contains("model_id") && printer["model_id"].get<std::string>() == type_str) {
|
||||
if (printer.contains("bed_temperature_limit")) {
|
||||
limit = printer["bed_temperature_limit"].get<int>();
|
||||
return true;
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
return result;
|
||||
}
|
||||
|
||||
bool DeviceManager::load_functional_config(std::string config_file)
|
||||
{
|
||||
std::ifstream json_file(config_file.c_str());
|
||||
|
|
|
@ -22,6 +22,7 @@
|
|||
#define FILAMENT_MAX_TEMP 300
|
||||
#define FILAMENT_DEF_TEMP 220
|
||||
#define FILAMENT_MIN_TEMP 120
|
||||
#define BED_TEMP_LIMIT 120
|
||||
|
||||
#define HOLD_COUNT_MAX 3
|
||||
|
||||
|
@ -499,6 +500,10 @@ public:
|
|||
|
||||
/* printing */
|
||||
std::string print_type;
|
||||
float nozzle { 0.0f };
|
||||
bool is_220V_voltage { false };
|
||||
|
||||
|
||||
int mc_print_stage;
|
||||
int mc_print_sub_stage;
|
||||
int mc_print_error_code;
|
||||
|
@ -536,6 +541,7 @@ public:
|
|||
PrintingSpeedLevel printing_speed_lvl;
|
||||
int printing_speed_mag = 100;
|
||||
PrintingSpeedLevel _parse_printing_speed_lvl(int lvl);
|
||||
int get_bed_temperature_limit();
|
||||
|
||||
/* camera */
|
||||
bool has_ipcam { false };
|
||||
|
@ -747,6 +753,7 @@ public:
|
|||
static bool is_function_supported(std::string type_str, std::string function_name);
|
||||
static std::vector<std::string> get_resolution_supported(std::string type_str);
|
||||
|
||||
static bool get_bed_temperature_limit(std::string type_str, int& limit);
|
||||
static bool load_functional_config(std::string config_file);
|
||||
};
|
||||
|
||||
|
|
|
@ -1590,6 +1590,7 @@ void StatusPanel::update_temp_ctrl(MachineObject *obj)
|
|||
if (!obj) return;
|
||||
|
||||
m_tempCtrl_bed->SetCurrTemp((int) obj->bed_temp);
|
||||
m_tempCtrl_bed->SetMaxTemp(obj->get_bed_temperature_limit());
|
||||
|
||||
// update temprature if not input temp target
|
||||
if (m_temp_bed_timeout > 0) {
|
||||
|
@ -2243,6 +2244,12 @@ void StatusPanel::on_set_bed_temp()
|
|||
long bed_temp;
|
||||
if (str.ToLong(&bed_temp) && obj) {
|
||||
set_hold_count(m_temp_bed_timeout);
|
||||
int limit = obj->get_bed_temperature_limit();
|
||||
if (bed_temp >= limit) {
|
||||
BOOST_LOG_TRIVIAL(info) << "can not set over limit = " << limit << ", set temp = " << bed_temp;
|
||||
bed_temp = limit;
|
||||
m_tempCtrl_bed->SetTagTemp(wxString::Format("%d", bed_temp));
|
||||
}
|
||||
obj->command_set_bed(bed_temp);
|
||||
}
|
||||
} catch (...) {
|
||||
|
|
Loading…